B) Concrete / Brick Wall Installation
Note: The concrete anchors must be used for concrete and brick installation.
1. Mount the bubble level (y) onto the wall plate at the position shown. With the help of an
assistant, place the wall plate onto the wall in the desired mounting location and check
the bubble level to ensure it is level. See Figure 3.
2. Mark six holes, minimum of 6 inches apart, to be used for securing the mount, and place
the wall plate aside. Locate the holes directly into the concrete or brick, never into the
mortar between the blocks. See Figure 3.
3. Drill six holes using an electric drill and 3/8" masonry drill bit to a depth of 3" at the
positions you marked.
4. Insert a concrete anchor (x) into each hole.
5. If necessary, a hammer can be used to lightly tap each concrete anchor into place so that
they are flush with the wall.
6. Once all of the concrete anchors are in place, move the wall plate back into position and
line up the mounting slots with the concrete anchor. Check the bubble level to verify that
the wall plate is level.
7. Insert lag bolts (v) and washers (w) into the concrete anchors as shown and tighten. Do
not fully tighten until all bolts are in place. See Figure 3.
CAUTION: Do not over tighten the bolts - doing so may cause unnecessary damage to the wall.
CAUTION: Do not release the wall plate until it is properly mounted and secured to the wall.